4% Buy This. Add To Cart. Hi. can somone explain to me how to wire it. If you have installed a circulating pump in your hot water system, you may have also decided that the efficient method to keep it running properly is to also install a thermostat and control. In-Stock. Aquastat is designed to operate Taco circulators for domestic hot water recirculation during peak demand periods. The basic components and connections in the circulator relay include: Green arrow: Line voltage in - 120VAC power to operate the circultor pump (white and black wires) usually labeled L1 and L2 I am working on setting up an indoor wood boiler, made by Uniterm in Denmark in 1974. ScottMcNab Member Posts: 40. Circulation Pump Aquastat. Aquastat Boiler Control Diagnostic Troubleshooting Guide. The simple controls mentioned above may be combined. I believe mounting the aquastat in either location would work being it should sense a temperature drop at either location. ... Grundfos - 595656 - 5/8" Piping - Aquastat Kit - 105-115 Degrees F - 1/2" Clip-on Mount. Buy Recirculation Pump Timer Direct and save. Ask a Question. Huge selection of Recirculating Pump Aquastats. While troubleshooting the problem I moved the aquastat onto the return recirculating pipe by the pump. Compare. Domestic Hot Water Recirculation Pump Timers and Aquastats ... An Aquastat similar to the Bell & Gossett AQ-3/4 shown above turns the pump on at 100°F and off at 120°F. What would be the best setting for the circ pump to come on and the correct differential? 3). Hi I recently had an L6006C aquastat installed to control the circulation pump for my Biasi cast iron conventional boiler (propane). $28.76. First, a recirculation system introduces a pump adjacent to the water heater, which helps hot water travel more quickly to the faucets, shower heads, … I am wondering how exactly I am to wire up the Honeywell L6006A aquastat to the Taco OOR-F6_1IFC circulator pump, so that the pump will turn on when the temperature rises to a certain level and turns off when the temperature lowers to a certain level. Skip to Main Content Skip to Search Filters Skip to Footer. The usage of a timer is recommended to limit the energy consumption. pump Aquastat Timer valve expansion Domestic hot water return line Parameters for recirculation application An Aquastat, with a 5° F differential to control the pump, is recommended for optimal temperature stability. Features: Automatically ON at 95°F and OFF at 115°F Adaptable to any "00" Series circulator Easy clip-on aquastat attaches directly to 3/4" pipe or a 1/2" sweat pump casing Many recirculator pumps have a built-in aquastat or timer. At present I have the circulating pump on a plug.when i want the pump on I plug it in.I bought a l6006c aquastat an want it to run the circulator only . stat to pump to plug. The two common options are a timer that periodically turns on the recirculation and an aquastat or thermostat that turns on the pump to keep water in the line at the desired temperature. if I have posted this question in wrong section please tell me since this is my first time on this site Originally I had the aquastat mounted on the hot water outlet pipe from the tank. Shown above, a hydronic heating system circulator pump relay control with its cover removed. November 2018 in THE MAIN WALL. Obviously, there are other control brands with more options for temperature. A way to control when the circulation pump runs.